Filter Results By:

Products

Applications

Manufacturers

Showing results: 436 - 450 of 469 items found.

  • Class 2 Sound Level Meter

    SP79 - Martindale Electric Co. Ltd

    The SP79 is a Class 2 sound level meter for on-site measurements in accordance with Noise at Work legislation in industrial and office environments. Featuring A and C frequency weighting and fast and slow time weighting, the compact design can be handheld, or mounted on a tripod for longer term monitoring of Min / Max values. Detailed recording and analysis can be made using the AC and DC outputs. The SP79 complies with BS EN 61672-1:2003 and is supplied with a detachable windshield and hard carry case. The large high contrast display includes both digital reading and analogue bar graph. An optional Class 2 sound level calibrator is available to verify accuracy before and after readings in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB.

  • Vibration Meters

    PCE Instruments

    A vibration meter is used in manufacturing for machine condition monitoring, product testing and quality assurance. Many machine maintenance technicians use vibration meter devices in tandem with sound level meters to analyze frequency. A vibration meter also can be used in civil engineering to measure the vibration of structures such as buildings, roads and bridges. In addition, specialized vibration meter devices can be used to measure the vibration of the human body. Any vibration meter will measure one or more of the following parameters: vibration acceleration, vibration velocity (speed) and / or vibration displacement.A vibration meter is typically a portable device with a memory for storing measurements. Most vibration meter models feature a built-in data logger for collecting and recording vibration measurement data over time. In this way, vibration measurement data can be acquired with great precision.

  • Partial Discharge Expert Diagnostic and Location System

    PDExpert - Power Monitoring and Diagnostic Technology Ltd.

    The PDExpert is PMDT's third level of Partial Discharge (PD) Expert Diagnostic and Location System. It is a powerful, portable, multi-channel system of impeccable design used to analyze and pinpoint PD signals coming from a power asset within centimeters while the power system is energized. The system consists of UHF, AE, HFCT and ultrasonic sensors, one advanced UHF/PD signal processing unit, one oscilloscope, filters and other accessories.The system employs ultra-high speed data acquisition and advanced digital signal processing technologies, compares the UHF, AE and HFCT signals of different frequency ranges to determine if it is PD or noise, and locates the source in power assets accurately by utilizing Acoustic-Electromagnetic Combination Location Technique, time Difference of Signals' Arrivals (TDOA), and 3D Positioning Technology.

  • Standard Electromagnetic Vibrator

    KD-9363-EM - King Design Industrial Co., Ltd.

    The purpose of vibration testing is to make a series of controllable vibration simulation in lab, no matter generated by natural or man-made vibration environment; such as waves, tidal flaps, wind, earthquake or rain and so on. It is to test if the product is capable of sustaining the vibration environment exerted from transporting or usage along its effective life cycle; and certify the standard of design & functional requirement of product. The value of vibration testing is to confirm the reliability of products and effectively screen out the bad products in factory; avoiding damages occurred at arrival; and to assess the failure analysis on the non-performing products; expecting to reach a high standard, high-reliability products. The vibration test stresses on the continuity and fatigue; and contributes to the understanding of product’s status under vibration circumstance in a normal environment; and avoids the product’s unpredictable damage caused under certain vibrating frequency for a long time.

  • PXIe-5672, 2.7 GHz, 20 MHz Bandwidth Digital Upconverter Included, PXI Vector Signal Generator

    779900-01 - NI

    2.7 GHz, 20 MHz Bandwidth Digital Upconverter Included, PXI Vector Signal Generator —The PXIe‑5672 features quadrature digital upconversion, which reduces waveform download and signal generation time. It is a general-purpose vector signal generator that can generate standard modulation formats such as AM, FM, PM, ASK, FSK, MSK, GMSK, PSK, QPSK, PAM, and QAM. The PXIe‑5672 delivers a highly flexible and powerful solution for scientific research, consumer electronics, communications, aerospace/defense, and semiconductor test applications as well as emerging areas including software defined radio, radio frequency identification (RFID), and wireless sensor networks. For specific communications standards, you can use various software add-ons to generate modulated signals according to standards such as WCDMA, DVB‑H, and ZigBee.

  • PXIe-5672, 2.7 GHz, 20 MHz Bandwidth Digital Upconverter Included, PXI Vector Signal Generator

    779900-03 - NI

    2.7 GHz, 20 MHz Bandwidth Digital Upconverter Included, PXI Vector Signal Generator —The PXIe‑5672 features quadrature digital upconversion, which reduces waveform download and signal generation time. It is a general-purpose vector signal generator that can generate standard modulation formats such as AM, FM, PM, ASK, FSK, MSK, GMSK, PSK, QPSK, PAM, and QAM. The PXIe‑5672 delivers a highly flexible and powerful solution for scientific research, consumer electronics, communications, aerospace/defense, and semiconductor test applications as well as emerging areas including software defined radio, radio frequency identification (RFID), and wireless sensor networks. For specific communications standards, you can use various software add-ons to generate modulated signals according to standards such as WCDMA, DVB‑H, and ZigBee.

  • PXIe-5672, 2.7 GHz, 20 MHz Bandwidth Digital Upconverter Included, PXI Vector Signal Generator

    779900-02 - NI

    2.7 GHz, 20 MHz Bandwidth Digital Upconverter Included, PXI Vector Signal Generator —The PXIe‑5672 features quadrature digital upconversion, which reduces waveform download and signal generation time. It is a general-purpose vector signal generator that can generate standard modulation formats such as AM, FM, PM, ASK, FSK, MSK, GMSK, PSK, QPSK, PAM, and QAM. The PXIe‑5672 delivers a highly flexible and powerful solution for scientific research, consumer electronics, communications, aerospace/defense, and semiconductor test applications as well as emerging areas including software defined radio, radio frequency identification (RFID), and wireless sensor networks. For specific communications standards, you can use various software add-ons to generate modulated signals according to standards such as WCDMA, DVB‑H, and ZigBee.

  • 400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device

    783151-01 - NI

    400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device - The USRP-2952 provides an integrated hardware and software solution for rapidly prototyping high-performance wireless communication systems. Built on the LabVIEW reconfigurable I/O (RIO) architecture, USRP RIO delivers an integrated hardware and software solution, so researchers can prototype faster and shorten time to results. You can prototype a range of advanced research applications that include multiple input, multiple output (MIMO); synchronization of heterogeneous networks; LTE relaying; RF compressive sampling; spectrum sensing; cognitive radio; beamforming; and direction finding. The USRP-2952 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) reference clock. GPS disciplining delivers improved frequency accuracy and synchronization capabilities.

  • 400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device

    783927-01 - NI

    400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device - The USRP-2952 provides an integrated hardware and software solution for rapidly prototyping high-performance wireless communication systems. Built on the LabVIEW reconfigurable I/O (RIO) architecture, USRP RIO delivers an integrated hardware and software solution, so researchers can prototype faster and shorten time to results. You can prototype a range of advanced research applications that include multiple input, multiple output (MIMO); synchronization of heterogeneous networks; LTE relaying; RF compressive sampling; spectrum sensing; cognitive radio; beamforming; and direction finding. The USRP-2952 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) reference clock. GPS disciplining delivers improved frequency accuracy and synchronization capabilities.

  • PD Signal Detection and Analysis via Ultra-High Frequency, Acoustic Emissions, High Frequency Current Transformer, and Transient Earth Voltage Sensors

    PDiagnostic Series - Power Monitoring and Diagnostic Technology Ltd.

    The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.​

  • Electromagnetic Radiation Tester

    Model KM 196 - Kusam Electrical Industries Limited

    • Unit : Electric Field : V/m; Magnetic Field : mT• Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT• Range : Electric Field : 1V/m ~ 1999V/m.• Magnetic Field : 0.01 mT ~ 19.99 mT• Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT• Reading Display : 3½ Digit Digital LCD display with Backlight.• Frequency Range : 5Hz ~ 3500MHZ• Sampling Time : About 0.4 second.• Measuring Mode : Dual Mode• Overload Alert : “1” appears on LCD• Sound & Light Alarm• Data Hold function.• Auto Power Off.• Average & Peak measurement.• Low Battery Indication.• Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH.• Power battery : 9V Battery.• Dimension : 63.6 x 31 x 125.8mm• Weight : Approx. 146g.

  • SMART III RF Probe

    Finna Sensors

    Finna Sensors’ Smart III RF Moisture Probe is appropriate in those situations where NIR use on conveying systems/web applications or RF flat plate sensor use on board type products are not sufficient. Examples include tanks, bins, barrels, drums, Super Sacks™, silos, etc. These applications require a probe type moisture meter where the probe is inserted into, and is surrounded by product. Since the probe generates a 3 inch diameter radio frequency field around the length of the probe, a significant volume of product is measured. As the product is slowly removed from the silo, and refilled from the top, it passes by the RF Probe, thereby providing a constant real time moisture measurement. Typical applications would include starches, distillers and brewers grains, granulated chemicals or food ingredients, whole grains such as corn kernels, rice, soybeans, tree nut stockpiles, etc.

  • Ensure Accurate Screening, Diagnosis & Monitoring

    Ultrasound QA Solutions - Sun Nuclear Corp.

    Gammex is the only ultrasound QA solutions manufacturer with expertise in medical physics since 1969.The 156 phantom helped establish the mammography repeatability and reproducibility standard: any mammography technologist (radiographer) at any time, on any machine, can provide the same image set to help detect breast cancer.We collaborated with clinical and academic thought leaders to develop our patented HE Gel and the first portable Doppler Flow phantoms in the world. HE (High Equivalency) Gel is what sets Gammex ultrasound products apart; it helps ensure all your transducers and system settings are fully tested across the entire frequency range from 2 to 18 MHz. Our HE Gel combined with our medical physics and quality control expertise gives you confidence with consistent diagnostic image quality in clinical applications.

  • HandyScope HS4 DIFF: 50 MS/s 100MHz BW, 4 Channel, USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS4-50-DIFF - TEAM SOLUTIONS, INC.

    * record length is 131060 samples * 128K samples on screen without loss of information * free settable pre trigger position, from 0 to 100% * easy time axis zoom using unique scaleable sroll bar slider * free adjustable sample frequency * vertical offset and gain adjustable with graphical shiftable and scaleable axis * WYSIWYG trigger level, slope and hysteresis adjustment using combined trigger control * Auto setup to reduce setting time with unknown signals * linear/quadratical interpolation * extended cursor measurements * all settings accessable through popup menus * storing and recalling reference signals * software math channel available * easy to use speedbutton toolbar for easy access of all functions * comment tags to mark specific events in the signal * color hardcopy supported * explanatory comments with all controls * envelope mode * averaging of signals

  • DC Bias Current Source

    TH1778A - Changzhou Tonghui Electronic Co., Ltd.

    The instrument adopts a new generation AC/DC superposition test theory to adapt test requirements for high precision and high frequency. The built-in embedded MCU with high-performance can quickly respond to host and slave machine condition or malfunction and make real time indication, which helps improve the work efficiency. The new designed friendly graphical operation interface, included 5-foot control modes and full touch operation provides convenience and efficiency for users. New file management system with easy, prompt and accurate operation can save a group of real-time setting file and 99 groups of user defined setting files. It can provide pushed information indication and cache 2 real-time information. Being provided with two modes of SCPI instruction systems, it is convenient to set up production lines or single machine test. Also, it can connect with any device with serial port and which refer to the SCPI instruction system design of this machine.

Get Help